Fan circuit.

54. An engine is overheating. The electric radiator cooling fan in the illustration does not operate under any condition. All of the following result in this condition EXCEPT:

  • A. A short to ground at point A.
  • B. An open at point B.
  • C. An open at point C.
  • D. An open at point D.
Simple fan circuit explained.

54.

Answer A is correct. All the other answers result in an inoperative fan motor. A short to ground at point A causes the fan motor to operate whenever the ignition is ON.

Answer B is wrong. An open at point B results in no fan operation because the fuse element is open.

Answer C is wrong. An open at point C results in no fan operation because the fan motor is not receiving power.

Answer D is wrong. An open at point D will prevent fan motor operation because it removes the circuit’s ground.